To view raw TCP packages, click `Comms` at the right bottom corner. You can double click the value of a specific address to modify it. Check the status of the modbus TCP Server Note that at a modbus client side, reading a disabled station(PLC ID) will only receive a exception returned from this tool.ĥ. Moreover, if a station(PLC ID) is reading by a modbus client, it will has a yellow border. You can click a specific one to disable it and it will turn into red from green. You can select modbus point type to display and type of modbus connection(TCP and RS232 available, RS232 is not covered in this tutorial) as highlighted below:Īs described above, this tool set all the 255 modbus IDs available, listed at the bottom of the window. Just double click the ModRSsim executable: If you don't have it installed, you can check them here: This is an open source software, requires Microsoft Visual C++ Redistributable for Visual Studio 2010. It's convenient for massive address testing. The feature of this tool is that it set all the 255 modbus IDs available. The trial version of ModSim and ModScan has limitation but it's sufficient for testing purpose. ModScan as HMI(aka modbus client or master) ModSim as PLC(aka modbus server or slave) ModRSsim2 as PLC(aka modbus server or slave) Before reading this note, I assume you already know what `Modbus` is and how `Modbus TCP` works. Here are two tools introduced, both on windows. When developing applications of modbus, you need a modbus Server or Client.